Oki OKIPOS X400 Programming Manual page 90

Hide thumbs Also See for OKIPOS X400:
Table of Contents

Advertisement

Command Structure <ESC>CA
Example: <ESC>CA
Placement: This command should be sent after the sensor type has been
Default:
Command Function To adjust the label sensor for unique media and ribbon combinations.
Input to Printer
<ESC>A
<ESC>CI2
<ESC>CA
<ESC>Z
Printer Output
There is no printer output for of this command. It will cause the printer to
feed about 6 inches while the characteristics of the label backing or eye-
mark are measured.
Special Notes 1.
The sensor is calibrated for the currently selected sensor type (Eye-Mark or
transmissive).
2.
The sensor must be recalibrated whenever the sensor type is changed or in-
correct label detection occurs.
3
When calibrating the sensor for the OKIPOS X400 Thermal Transfer unit operating in
the thermal transfer mode, the ribbon must be installed in the printer.
All manuals and user guides at all-guides.com
Calibrate Sensor
selected with the <ESC>CI command. It should not be included
with print job commands.
There is no default for this command.
88