3. Enter all information required about each GX Device
G X D E V I C E S - D e f i n i t i o n
F i e l d D a t a
ID Unique record ID assigned by MPU955 Admin Console as a device is added, in order to
identify one device to the system. 1 to 1,024.
MPU955 Admin Console automatically generates this number in consecutive order. Upon
adding devices, the system will automatically assign the next available number.
Component ID and sequence ID numbers are used primarily in the permission tabs to identify
one component or sequence from another in row and column style. Since logical and local
numbers are not necessarily unique or consecutive; and the permission grids are displayed as
consecutive, unique numbers; MPU955 Admin Console generates these ID numbers.
I/F Numeric Ethernet interface number identifying a port on a CPU where the device will connect.
0 to 15, though generally 0, 1, or 2.
IPA Unique Internet Protocol address assigned by the system administrator. Dotted decimal, 15
characters (including dots). Example: 128.010.050.125
EA Numeric address for an Ethernet controller. Dotted hexadecimal Example: 23.56.82.13.60.82
(Also known as MAC address.)
Name A name for the device. Alphanumeric, 16 characters.
Location A name for the device location. Alphanumeric, 16 characters.
Ser. Manufacturer's serial number. Alphanumeric, 16 characters.
Encoder / Decoder
If the device is an encoder, select the Encoder button, and choose the range of input ports from
(device type)
the Input Ports drop-down menu. The range must be unique for each encoder.
For GXDIN, select its Input Ports; for GXDOUT, select its Output Ports; and for GXRS485,
enter its Port number.
Enter the hexadecimal Address [SW1] in the A, B, and C fields.
If the device is a decoder, select the Decoder button, and choose the range of output ports from
the Output Ports drop-down menu. The range must be unique for each decoder.
For GXDOSD Output Ports, select the output ports from the drop-down menu.
Enter the hexadecimal Address [SW1] in the A, B, and C fields.
4. Click the green check mark to save
You will remain in the "Add" mode, allowing you to enter information about another
device.
5. To exit the "Add" mode, click the red X
You will exit the "Add" mode.
6. To edit a configured device, highlight a device ID and click the Edit
button
You may also double-click on a device ID in the list to enter the edit mode.
7. Edit the desired fields