Airflow Support; Drive Bay Population; Figure 17. Cpu / Memory Air Duct; Table 20. Non-Redundant Fan Connector Pin Assingment - Intel SR2612UR Product Specification

Hide thumbs Also See for SR2612UR:
Table of Contents

Advertisement

Cooling Subsystem

Table 20. Non-redundant Fan Connector Pin Assingment

Pin
1
2
3
4
4.3

Airflow Support

Fan
System Fan #1 and #2
System Fan #3
System Fan #4
To control airflow within the system, the system uses a CPU air duct to isolate and direct airflow
to three critical zones: power supply zone, PCI zone, and CPU/memory zone.
4.4

Drive Bay Population

To maintain proper air pressure within the system, all hard drive bays must be populated with
either a hard drive or drive blank.
30
Signal Name
Return
Return path to ground
12V
Power for fan
FOO
Fan Tachometer signal
PWM
Fan speed control signal

Table 21. Non-redundant Cooling Zones

Cooling
Zone
Processor
Primary cooling for CPU, memory, and hard
and
drives
Memory
PCI
Primary cooling for PCI cards, Intel
chipset IOH, and hard drives
Power
Primary cooling for hard drives and the power
Supply
supply modules.

Figure 17. CPU / Memory Air Duct

Intel order number E76293-003
Intel® Server System SR2612UR TPS
Description
Description of greatest cooling influence
®
S5520
Revision 1.3

Advertisement

Table of Contents
loading

Table of Contents