Table 36. Post Error Beep Codes - Intel SR2612UR Product Specification

Hide thumbs Also See for SR2612UR:
Table of Contents

Advertisement

Intel® Server System SR2612UR TPS
Error Code
94C6
LPC component encountered a controller error.
94C9
LPC component encountered a resource conflict error.
9506
ATA/ATPI component encountered a controller error.
95A6
PCI component encountered a controller error.
95A7
PCI component encountered a read error.
95A8
PCI component encountered a write error.
9609
Unspecified software component encountered a start error.
9641
PEI Core component encountered a load error.
9667
PEI module component encountered an illegal software state error.
9687
DXE core component encountered an illegal software state error.
96A7
DXE boot services driver component encountered an illegal software state error.
96AB
DXE boot services driver component encountered invalid configuration.
96E7
SMM driver component encountered an illegal software state error.
0xA022
Processor component encountered a mismatch error.
0xA027
Processor component encountered a low voltage error.
0xA028
Processor component encountered a high voltage error.
0xA421
PCI component encountered a SERR error.
0xA500
ATA/ATPI ATA bus SMART not supported.
0xA501
ATA/ATPI ATA SMART is disabled.
0xA5A0
PCI Express* component encountered a PERR error.
0xA5A1
PCI Express* component encountered a SERR error.
0xA5A4
PCI Express* IBIST error.
0xA6A0
DXE boot services driver Not enough memory available to shadow a legacy option ROM.
POST Error Beep Codes
The following table lists the POST error beep codes. Prior to system video initialization, the
BIOS uses these beep codes to inform users on error conditions. The beep code is followed by
a user-visible code on the POST Progress LEDs. For complete details, refer to the Intel
S5500/S5520 Server Board Family BIOS External Product Specification.
Beeps
Error Message
3
Memory error
The Integrated BMC may generate beep codes upon detection of failure conditions. Beep
codes are sounded each time the problem is discovered, such as on each power-up attempt,
but are not sounded continuously. Codes that are common across all Intel server boards and
systems that use same generation chipset are listed in the following table. Each digit in the
code is represented by a sequence of beeps whose count is equal to the digit. For complete
details, refer to the Intel
External Product Specification.
Revision 1.3
Error Message

Table 36. POST Error Beep Codes

POST Progress Code
0xE8, 0xEB, 0xED,
0xEE
®
Server System Integrated Baseboard Management Controller Core
Intel order number E76293-003
Appendix C: POST Code Errors
Description
System halted because a fatal error related to the memory
was detected.
Response
No Pause
Pause
No Pause
No Pause
No Pause
No Pause
No Pause
No Pause
Halt
Halt
Halt
No Pause
Halt
Pause
No Pause
No Pause
Halt
No Pause
No Pause
No Pause
Halt
Pause
No Pause
®
69

Advertisement

Table of Contents
loading

Table of Contents