Setting the start-up replenishment function

This function assures an automatic developer and fixer replenishment every
time the processor is switched on. This setting should be activated if the proces-
sor is used on an irregular basis (only a few days per week).
The default setting is OFF.
Refer to the table for recommended start-up developer and fixer replenishment
settings, depending on the specific workload.
more than 5 m² film/day
daily use
irregular use
400 ml/m²
Related setting: Standby developer and fixer replenishment - jog cycle
more than 5 m² film/day
daily use
irregular use
OFF
more than 5 m² film/day
daily use
irregular use
OFF
The start-up replenishment rate is not adjustable during film processing.
If you do not comply with the recommended replenishment rates, the
optimal processing stability is no longer guaranteed and sensitometric
variations might occur.
1280C GB 20001204
Related setting: Developer replenishment rate
3 to 5 m² film/day
daily use
400 ml/m²
600 ml/m²
3 to 5 m² film/day
daily use
OFF
OFF
Start-up replenishment function
3 to 5 m² film/day
daily use
ON
OFF
less than 3 m² film/day
irregular use
daily use
600 ml/m²
600 ml/m²
less than 3 m² film/day
irregular use
daily use
OFF
less than 3 m² film/day
irregular use
daily use
ON
OFF
irregular use
600 ml/m²
irregular use
ON
ON
irregular use
ON