2. Push the ↑ button until the wrench (
3. Change the parameter number to enable the desired timer. When the correct parameter number is showing,
press the Auto button to enter it. Press the Manual/Start (I) button to change it to 1 to enable the timer and press
the Auto button to save it.
Note: The ↑ and ↓ buttons will adjust the hundredths place of the parameter number and the Manual/Start (I) and
Stop/Reset (O) buttons will adjust the low digits. Up to eight events can be scheduled at a time.
4. Change the parameter number to adjust the time of the desired event and then press the Auto button to enter
it. Press the Manual/Start (I) and Stop/Reset (O) buttons to change the time. Holding down either button will
change the time faster. Press the Auto button to save the time.
5. Change the parameter number to adjust the day of the week and press the Auto button to enter it. Press the
Manual/Start (I) and Stop/Reset (O) button to change to the desired day and press the Auto button to save it.
Note: Only one day can be chosen per event if parameter 903 is "1" (monthly).
6. Change the parameter number to adjust duration of the timer and press the Auto button to enter it. Press the
Manual/Start (I) or Stop/Reset (O) buttons to change the duration and press the Auto button to save it.
Note: If any of the scheduled time slots are currently active, the controller will begin the starting sequence and start
the unit, provided there are no shutdown conditions present.
The times for the scheduled timers/events are based on the internal clock for the controller. Use the corresponding
parameters to adjust to the correct time of the day and correct date.
This table lists the parameters needed to schedule an event and to adjust the clock within the controller.
Note: If parameter 902 is "0", then the auto exercise timer is enabled, and if it is "1", then the autolight timer is enabled.
Parameter
901
Enable Scheduler
902
Schedule Run On or Off Load
903
Schedule Period
904
Scheduler (1) Start Time
905
Scheduler (1) Start Day
906
Scheduler (1) Start Week
907
Scheduler (1) Duration
908
Scheduler (2) Start Time
909
Scheduler (2) Start Day
910
Scheduler (2) Start Week
911
Scheduler (2) Duration
912
Scheduler (3) Start Time
913
Scheduler (3) Start Day
914
Scheduler (3) Start Week
915
Scheduler (3) Duration
916
Scheduler (4) Start Time
917
Scheduler (4) Start Day
918
Scheduler (4) Start Week
919
Scheduler (4) Duration
) icon is selected. Push the Auto button to enter the parameters.
Description
Configuration Parameters - Scheduler
Details
On (1), Off (0)
On (1), Off (0)
Weekly (0), Monthly (1)
0:00:00
0 (1=Monday)
1,2,3,4
0:00:00
0:00:00
0 (1=Monday)
1,2,3,4
0:00:00
0:00:00
0 (1=Monday)
1,2,3,4
0:00:00
0:00:00
0 (1=Monday)
1,2,3,4
0:00:00
29