Appendix; Maintaining The Unit - Samsung MWR-WW10JN User Manual

Air to water heat pump wired remote controller
Hide thumbs Also See for MWR-WW10JN:
Table of Contents

Advertisement

Maintaining the Unit

Maintenance activities
In order to ensure optimal availability of the unit, a number of checks and inspections on the unit and
the field wiring have to be carried out at regular intervals, preferably yearly.
This maintenance should be carried out by SAMSUNG local technician. Besides keeping the remote
controller clean by means of a soft damp cloth, no maintenance is required by the operator.
WARNING
During longer periods of standstill, e.g. during summer with a heating only application, it is very
important NOT TO SWITCH OFF THE POWER SUPPLY towards the unit.
Switching off the power supply stops the automatic repetitive movement of the motor in order to
prevent it from getting jammed.
Emergency heating / Emergency hot water supply
<Emergency heating_(when using #4021)>
Heating function is performed only by the backup heater if the outdoor unit malfunctions (available only
when a backup heater is connected).
Enabling the function : Turn off the Control kit Dip S/W #1, and then turn the power off and on.
Disabling the function : Turn on the Control kit Dip S/W #1, and then turn the power off and on.
Default operation : Automatic heating is performed at a set temperature of 35°C.
52 English