How to upload or download field settings (example)

1 Insert an SD card into the Sub PBA SD Card slot on the Hydro unit.
2 Select Field Setting Value in the Service mode.
3 Press the
or
button to select FSV Upload/Download.
NOTE
Upload: Uploads the FSV data of the Hydro unit to the SD card.
Download: Downloads the FSV data of the SD card to the Hydro unit.
When connecting between the MWR-WW10** wired remote controller and an upper-level controller, the
settings for FSV (4061) must be changed not to use the 2-zone control.