Theben RAMSES 811 top3 Manual page 9

Digital clock thermostat

Advertisement

L The functions in this submenu have to be set by the quali-
fied electrician.
In the settings, language, temperature (comfort, eco (setback),
frost protection), wall compensation, optimisation, etc. can be
set.
1. Set wall compensation
See Page 5 above.
2. Set controller
For the behaviour of a hysteresis controller, see Page 5.
For the behaviour of a pulse duration controller, see
Page 5.
3. External input
The external input can be configured for various external sen-
sors, see Page 6.
Error indicator on RAMSES top3
L If the external input is set to "floor" or "room tempera-
ture", an appropriate temperature sensor has to be con-
nected. If this sensor is missing, an error indicator flashes
in the device. The same error also appears in the Start
menu in the app.
4. Set optimisation
The optimisation function allows you to achieve a certain
room temperature at a desired time switch, see Page 6.
5. Set summer/winter time
L The summer/winter time rule for Central Europe is preset
(see also Page 7).
You can choose between
0 → Off (no summer-winter time changeover)
1 → Central Europe (default)
2 → Western Europe
3 → Eastern Europe
9