Dell PowerEdge R6615 Installation And Service Manual page 89

Table of Contents

Advertisement

NOTE:
Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 71. 10 x 2.5-inch SAS4/SATA RAID (w/ FPERC12)
Order
From
1
SIG_PWR_1 (system board power connector)
2
SL1 (signal connector on system board)
3
SL3 (signal connector on system board)
4
CTRL_SRC_SB1 (front PERC)
5
CTRL_SRC_SA1_PA1 (front PERC)
Figure 55. 10 x 2.5-inch w/ 4x Uni G4 (w/ FPERC11)
NOTE:
Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 72. 10 x 2.5-inch w/ 4x Uni G4 (w/ FPERC11)
Order
From
1
SIG_PWR_1 (system board power connector)
2
SL1 (signal connector on system board)
3
CTRL_SRC_SB1 (front PERC)
4
SL7 (signal connector on system board)
5
SL8 (signal connector on system board)
To
BP_PWR_1 (backplane power connector)
CTRL_DST_PA1 (front PERC)
CTRL_DST_PB1 (front PERC)
BP_DST_SB1 (backplane signal connector)
BP_DST_SA1 (backplane signal connector)
To
BP_PWR_1 (backplane power connector)
CTRL_DST_PA1 (front PERC)
BP_DST_SB1 (backplane signal connector)
BP_DST_PB2 (backplane signal connector)
BP_DST_PA3 (backplane signal connector)
Installing and removing system components
89