Flight Instruments
G-METER
Whenever the G load on the airplane goes above +2.1G or below -0.5G the HSI is
temporally replaced with a large graphical G-meter. To remove the G-meter press the
CLR Key. Regardless of the current G load, the HSI can be replaced with a G-meter by
changing the 'G METER' setting on the PFD setup page. The G-meter will be displayed
until the setting is changed to auto or the power is cycled. Small white triangles are
used to indicate the minimum and maximum recorded G loads. Refer to the G3X
installation manual for more information on configuring the G-meter.
Manually displaying the G-meter:
1) From the full screen PFD and/or split screen PFD Page, press the MENU Key.
2) Move the FMS Joystick to highlight G METER.
3) Turn the FMS Joystick to select 'ON (NO HSI)'.
Resetting the G-meter minimum and maximum markers:
1) From the full screen PFD and/or split screen PFD Page, press the MENU Key.
2) Press the RESET G Softkey to reset the minimum and maximum recorded G
loads.
Maximum
recorded
G load
Minimum
recorded
G load
78
G-meter
Garmin G3X Pilot's Guide
G-meter
pointer
190-01115-00 Rev. G