Prerequisites For Installation Completion By Ssr - IBM Elastic Storage System 3200 Hardware Planning And Installation Manual

Hide thumbs Also See for Elastic Storage System 3200:
Table of Contents

Advertisement

Netmask: 255.255.255.0
BMC Network IPs:
Subnet: 10.0.0.0/24
IP Address: 10.0.0.1 (C11-T2)
IP Address: 10.0.0.100 (HMC1)
Netmask: 255.255.255.0
POWER9 EMS
Table 21. EMS management connections
Physical interface
Port C11-T1
Port C11-T2
Left canister best practices
Ensure that each IP in the worksheet is on the same subnet. Recommended subnet is /24
(255.255.255.0).
Management Network IPs:
Subnet: 192.168.45.0/24
IP Address: 192.168.45.50
Netmask: 255.255.255.0
BMC Network IPs:
Subnet: 10.0.0.0/24
IP Address: 10.0.0.120 (BMC)
Netmask: 255.255.255.0
• Logical interface: mgmt
• Physical interface: Port 1
Right canister best practices
Ensure that each IP in the worksheet is on the same subnet. Recommended subnet is /24
(255.255.255.0).
Management Network IPs:
Subnet: 192.168.45.0/24
IP Address: 192.168.45.51
Netmask: 255.255.255.0
BMC Network IPs:
Subnet: 10.0.0.0/24
IP Address: 10.0.0.121 (BMC)
Netmask: 255.255.255.0
• Logical interface: mgmt
• Physical interface: Port 1

Prerequisites for installation completion by SSR

Customers must fill the Installation worksheet for the SSR to start installation. This process must be done
by using the Technical Delivery Assessment (TDA) process. The worksheet describes the IP addresses
that the SSR sets on each node. If the worksheet is not completed, the SSR might confirm with the
personnel at the data center and use default IP addresses listed.
Racked or rackless installation:
62  IBM Elastic Storage System 3200: Hardware Planning and Installation Guide
Logical interface
mgmt
fsp