Trane Horizon OABD Series Installation, Operation And Maintenance Manual page 10

Outdoor air unit
Table of Contents

Advertisement

Model Number Descriptions
Digit 22 — Heat Capacity (Primary
Heat Source)
IF
ELEC
0
=
No Heat
No Heat No Heat
A
=
50 MBh
10 kW
B
=
75 MBh
20 kW
C
=
100 MBh
24 kW
D
=
125 MBh
28 kW
E
=
150 MBh
32 kW
F
=
200 MBh
40 kW
G
=
250 MBh
48 kW
H
=
300 MBh
60 kW
J
=
350 MBh
68 kW
K
=
400 MBh
79 kW
L
=
500 MBh
99 kW
M =
600 MBh
111 kW
N
=
700 MBh
119 kW
P
=
800 MBh
139 kW
R
=
1000 MBh 159 kW
S
=
179 kW
T
=
199 kW
U
=
215 kW
X
=
Special Heater Option
Digit 23 — Heat Capacity
(Secondary Heat Source)
IF
ELEC
0
=
No Secondary
No Secondary Heat
Heat
A
=
50 MBh
10 kW
B
=
75 MBh
20 kW
C =
100 MBh
24 kW
D =
125 MBh
28 kW
E
=
150 MBh
32 kW
F
=
200 MBh
40 kW
G =
250 MBh
48 kW
H =
300 MBh
60 kW
J
=
350 MBh
68 kW
K
=
400 MBh
79 kW
L
=
500 MBh
99 kW
M =
600 MBh
111 kW
N =
700 MBh
119 kW
P
=
800 MBh
139 kW
R =
1000 MBh
159 kW
S
=
179 kW
T
=
199 kW
U =
215 kW
10
Digit 24 — Corrosive Environment
Package
0
=
No Corrosive Package
Hot Water
1
=
S/S Interior, S/S Evap Coil Casing
2
=
S/S Interior, Eco Coated Coils
1 Row/10 FPI
3
=
S/S Interior,
Copper/Copper Evap Coil
1 Row/12 FPI
4
=
S/S Coil Casing
1 Row/14 FPI
5
=
S/S Interior Casing
2 Row/10 FPI
6
=
Eco-Coated Coils
7
=
S/S Coil Casing with
2 Row/12 FPI
Eco-Coated Coils
2 Row/14 FPI
8
=
Copper/Copper Evap,
3 Row/10 FPI
HGRH Coils
9
=
Corrosion Resistant Package
3 Row/12 FPI
Digit 25, 26 — Unit Controls
3 Row/14 FPI
00 =
Non-DDC – Electromechanical
AC =
Trane – Discharge Air Control
w/BACnet
AD =
Trane – Space Control
w/BACnet (No Display)
AF =
Trane – Discharge Air Control
w/BACnet w/Display
AG =
Trane – Space Control
w/BACnet w/Display
AL =
Trane – Multi-Zone VAV Control
w/BACnet w/Display
AN =
Trane – Multi-Zone VAV Control
w/BACnet (No Display)
AP =
Trane – Single-Zone VAV Control
w/BACnet w/Display
AR =
Trane – Single-Zone VAV Control
w/BACnet (No Display)
BB =
Trane – Space Control w/BACnet
(No Display) w/Thumbwheel
BC =
Trane – Space Control w/BACnet
w/Display w/Thumbwheel
BG =
Trane – Single-Zone VAV Control
w/BACnet w/Display w/
Thumbwheel
BJ =
Trane – Single-Zone VAV Control
w/BACnet (No Display) w/
Thumbwheel
CA =
Trane – Lab Space Control w/
BACnet (No Display)
CB =
Trane – Lab Space Control w/
BACnet w/Display
CC =
Trane – Lab Discharge Air Control
w/BACnet (No Display)
CD =
Trane – Lab Discharge Air Control
w/BACnet w/Display
CE =
Trane – Lab Multi-Zone VAV
Control w/BACnet (No Display)
CF =
Trane – Lab Multi-Zone VAV
Control w/BACnet w/Display
CG =
Trane – Lab Space Control w/
BACnet (No Display) w/
Thumbwheel
CH =
Trane – Lab Space Control w/
BACnet w/Display w/Thumbwheel
DA =
Trane – Horizon Thrive Control w/
BACnet (No Display)
DB =
Trane – Horizon Thrive Control w/
BACnet w/Display
XX =
Control Special
®
(No Display)
Digit 27 — Powered Exhaust Fan
Motor (PFM) and Exhaust Dampers
0
=
No Powered Exhaust
1
=
Direct Drive w/VFD and Gravity
Dampers
2
=
Direct Drive (VFD by Others)
5
=
Special Motor Option
6
=
Direct Drive w/VFD and
Barometric Relief Damper
7
=
Direct Drive w/VFD and Isolation
Dampers w/End Switch
8
=
Barometric Relief Dampers
(NO PFM)
Digit 28 — Powered Exhaust Fan
Wheel
0
=
No Powered Exhaust
A
=
120
B
=
120.6
C
=
140
D
=
140.6
E
=
160
F
=
160.6
G
=
180
H
=
180.6
J
=
200
K
=
200.6
L
=
180 X 2
M =
180.6 X 2
Digit 29 — Powered Exhaust Fan
Motor Power
0
=
No Powered Exhaust
E
=
1 hp – 1800 rpm
F
=
1 hp – 3600 rpm
G
=
1.5 hp – 1800 rpm
H
=
1.5 hp – 3600 rpm
J
=
2 hp – 1800 rpm
K
=
2 hp – 3600 rpm
L
=
3 hp – 1800 rpm
M =
3 hp – 3600 rpm
N
=
5 hp – 1800 rpm
P
=
5 hp – 3600 rpm
R
=
7.5 hp – 1800 rpm
S
=
7.5 hp – 3600 rpm
T
=
10 hp – 1800 rpm
U
=
10 hp – 3600 rpm
V
=
15 hp – 1800 rpm
W =
15 hp – 3600 rpm
Digit 30 — UC600 Hardware
Template
-
=
Prior to v8.0
1
=
v8.X, v9.X, or v10.X
2
=
v11.0 / Thrive v2.1
3
=
v11.1 - v11.3 / Thrive v2.1
4
=
v12.0 / Thrive v2.2
Digit 31 — ERV (Requires Powered
Exhaust)
0
=
No ERV
A
=
ERV – Composite Construction
B
=
ERV – Composite Construction
with Frost Protection w/VFD
C
=
ERV – Composite Construction
with Bypass
D
=
ERV – Composite Construction
with Frost Protection and Bypass
E
=
ERV – Aluminum Construction
F
=
ERV – Aluminum Construction
with Frost Protection w/VFD
OAU-SVX007A-EN