Fault 10 Motor Stalled
InfoCenter Display:
Fault Description
The motor was at zero rpm for more than 3 seconds during operation.
Conditions for Setting the Fault
Heavy cutting conditions or a cutting unit malfunction is causing excessive motor drag, resulting in an
overcurrent or overvoltage condition.
Recommended Service Actions
Step 1: Verify that the fault repeats.
1.
Safely stop the machine and all attachments.
2.
Shut off the machine by rotating the key switch to the O
3.
Turn on the machine by rotating the key switch to the O
Note:
If the fault does not repeat immediately, duplicate the operation of the machine when the fault
occurred.
4.
Look at the InfoCenter and see if the fault has repeated.
Pass
The fault did not repeat. Go to
Note:
If the fault does not repeat, an isolated event has occurred.
Fail
The fault repeated. Go to Step 2.
Step 2: Check the charge level of the battery.
1.
Move the key switch to the O
2.
On the InfoCenter, verify that the battery charge indicator shows at least one full block.
1. Battery charge indicator
Motor Stalled
Returning the Machine to Service (page 20)
position.
N
Figure 41
57
position.
FF
position.
N
and follow the steps listed.
g364041