Replacing the LSI1600 card with LSI320-2

Use this procedure to replace a failed LSI1600 RAID card.
Copyright © 2007, Nortel Networks
.
Press Enter to End the Array.
Result: The blinking stops.
Press F10 to configure the logical drive.
Press the space bar to select Configuration Array.
Result: Span-1 appears in the box opened for the A01 logical drive.
Press F10 to configure the logical drives.
Result: The system prompts you for each of the logical drives to
consecutively select:
RAID 1;
Size: accept the size displayed
Accept
SPAN = NO
Change the last value to NOSPAN if required.
Highlight Accept and press Enter twice to accept these new values.
Result: The system prompts you to save the configuration.
Highlight YES and press Enter.
Press ESC twice to exit the submenus.
In the Management menu, choose the Initialize submenu.
Press F2 to select the logical drive.
Press F10 and consecutively select YES to initialize the drive pack.
When the initialization is complete, press any key to return to the
Management menu.
Press ESC to exit the utility. Save the configuration when prompted.
Press Ctrl+Alt+Delete as indicated by the menu to reboot.
Nortel CallPilot
703t Server Maintenance and Diagnostics
NN44200-702 01.03 Standard
5.0 3 April 2007
—End—