114 Chapter 3 Configuring Remote Network Monitoring (RMON)
Field
RisingThreshold A threshold for the sampled statistic. When the current sampled
RisingEventIndex The index of the eventEntry that is used when a rising threshold
FallingThresholdA threshold for the sampled statistic. When the current sampled
FallingEventIndex T he index of the eventEntry that is used when a falling threshold
Owner
Status

Events

RMON events and alarms work together to provide notification when
values in the network are outside of a specified range. When values pass
the specified ranges, the alarm is triggered. The event specifies how the
activity is recorded.
Copyright © 2005 - 2007, Nortel Networks
.
Description
value is greater than or equal to this threshold, and the value
at the last sampling interval was less than this threshold, a
single event is generated. A single event is also generated if
the first sample after this entry becomes valid is greater than or
equal to this threshold and the associated alarmStartupAlarm
is equal to risingAlarm(1) or risingOrFallingAlarm(3). After a
rising event is generated, another such event is not generated
until the sampled value falls below this threshold and reaches
the alarmFallingThreshold.
is crossed. The eventEntry identified by a particular value of
this index is the same as identified by the same value of the
eventIndex object. If there is no corresponding entry in the
eventTable, then no association exists. In particular, if this value
is zero, no associated event is generated, because zero is not a
valid event index.
value is less than or equal to this threshold, and the value at
the last sampling interval was greater than this threshold, a
single event is generated. A single event is also generated if
the first sample after this entry becomes valid is less than or
equal to this threshold and the associated alarmStartupAlarm is
equal to fallingAlarm(2) or risingOrFallingAlarm(3). After a falling
event is generated, another such event is not generated until
the sampled value rises above this threshold and reaches the
alarmRisingThreshold.
is crossed. The eventEntry identified by a particular value of
this index is the same as identified by the same value of the
eventIndex object. If there is no corresponding entry in the
eventTable, then no association exists. In particular, if this value
is zero, no associated event is generated, because zero is not a
valid event index.
The network management system that created this entry.
The status of this alarm entry.

Nortel Ethernet Routing Switch 5500 Series

Configuration - System Monitoring

NN47200-505 03.01 Standard

5.1 27 August 2007

Advertisement

Table of Contents
loading

This manual is also suitable for:

5530-24tfd55205510-24t5510-48t5520-24t-pwr5520-48t-pwr

Table of Contents