Book A
Model 5399 Remote Access Concentrator Network Administrator's Guide for UNIX
Table B-35. Modem Statistic Objects (continued)
MIB Object Name
mdmStatTxBaudRate
mdmStatRxBaudRate
mdmStatBeginSignalQ
mdmStatCurrSignalQ
mdmStatBeginRxLineLevel
mdmStatCurrRxLineLevel
mdmStatModulationMode
(continued on next page)
Chapter 2
Simple Network Management Protocol (SNMP)
Description
Symbol rate is the rate at which symbols
that carry data are generated. Symbol rate
limits and options apply to modem v.34.
Symbol rate is the rate at which symbols
that carry data are received. Symbol rate
limits and options apply to modem v.34.
The quality of the line signal in decibels
(db) at the beginning of the call.
(0 db = worst, 15 db = best).
Typical values should be 14 db - 15 db.
Current signal quality in decibels (db).
(0 db = worst, 15 db = best)
Typical values should be 14 db - 15 db.
Receive signal level in decibels (db) at the
time the call was initiated. (0 db to -45db)
Typical values should be -12 db to -30db.
Current receive signal level in decibels
(db). (0 db to -45db) Typical values should
be -12 db to - 30 db.
The negotiated modulation mode.
v34bis (1) v34 (2) v32-v32bis (3)