2-16 General Description
Virtual LCD indications when STATUS lamp is flashing amber
On-screen message
Mem Reconfigured
Mem Err Disable
CPU Reconfigured
HDD X Fault
E-Keying Error
Location Error
Cooling Error
Proc1 Therm % 07
Proc2 Therm % 07
AmbientTempAlm07
DAS AirTempAlm07
AmbientTempAlm00
DAS AirTempAlm00
Battery Alm XX
Description
The memory is degraded.
Correctable memory error frequently
occurs.
The CPU is degraded.
An error was detected in hard disk
drive in slot X. X denotes the slot
number with 1-origin that contains
the failed hard disk drive.
In the Blade Enclosure, combination
of installation locations of CPU
blade, mezzanine card, and switch
module is not correct. Thus, an
unconformity of interface signal was
detected and the CPU blade failed
to power on.
In the Blade Enclosure, the
installation location of CPU blade is
incorrect, or the installation locations
of the fan and CPU blade are
incorrect. Thus, the CPU blade
failed to power on.
In the Blade Enclosure, the number
of fans installed is insufficient or the
installed fan is faulty. Thus, the CPU
blade failed to power on due to
insufficient cooling power.
A high temperature warning was
detected in CPU#1.
A high temperature warning was
detected in CPU#2.
A high temperature warning was
detected in CPU unit.
A high temperature warning was
detected in storage unit.
A low temperature warning was
detected in CPU unit.
A low temperature warning was
detected in storage unit.
A battery voltage warning was
detected.
XX=07: Upper limit warning
XX=00: Lower limit warning
Action
1. Check the installation status of
the DIMM.
2. Replace the DIMM.
1. Check the installation status of
the CPU.
2. Replace the CPU.
Check the hard disk drive.
Refer to the User's Guide of the
Blade Enclosure for the correct
installation locations.
Refer to the User's Guide of the
Blade Enclosure to check if the CPU
blade is installed in the correct
location.
Check the installation locations of
the fan and CPU blade.
Check if the fans in the Blade
Enclosure work normally.
Check if the heat sink of the CPU
blade works normally.
Refer to the User's Guide of the
Blade Enclosure to make sure that a
sufficient number of fans are
installed.
Check if the fans and CPU blades
are installed in the correct locations.
Check if the ambient temperature of
the installation location satisfies the
operating conditions.
Check if the ambient temperature of
the installation location satisfies the
operating conditions.
1. Check the installation status of
the battery.
2. Replace the battery.