2-14 General Description
On-screen message
Proc1ThermalTrip
Proc2ThermalTrip
Proc1 Therm % 09
Proc2 Therm % 09
AmbientTempAlm09
DAS AirTempAlm09
AmbientTempAlm02
DAS AirTempAlm02
Battery Alm XX
Proc1 Vccp AlmXX
Proc2 Vccp AlmXX
BB FSBvtt Alm XX
BB DIMMvtt AlmXX
BB +1.2v Alm XX
BB +1.5v Alm XX
BB +3.3v Alm XX
BB +5v Alm XX
BB +1.2vs Alm XX
BB +1.5vs Alm XX
BB +1.25vs AlmXX
BB +3.3vs Alm XX
BB +5vs Alm XX
BB +12vs Alm XX
Description
Forced power-off occurred due to
a thermal error in CPU#1.
Forced power-off occurred due to
a thermal error in CPU#2.
A high temperature error was
detected in CPU#1.
A high temperature error was
detected in CPU#2.
A high temperature error was
detected in CPU unit.
A high temperature error was
detected in storage unit.
A low temperature error was
detected in CPU unit.
A low temperature error was
detected in storage unit.
A battery voltage alarm was
detected.
XX=09: Upper limit alarm
XX=02: Lower limit alarm
A voltage alarm on CPU unit was
detected.
XX=09: Upper limit alarm
XX=02: Lower limit alarm
Action
Check if the fans in the Blade
Enclosure work normally.
Check the heat sink of the CPU
blade.
Refer to the User's Guide of the
Blade Enclosure to make sure that
a sufficient number of fans are
installed.
Check if the fans and CPU blades
are installed in the correct locations.
Check if the ambient temperature of
the installation location satisfies the
operating conditions.
Check if the ambient temperature of
the installation location satisfies the
operating conditions.
1. Check the installation status of
the battery.
2. Replace the battery.
Replace the CPU blade.