Overview - Agilent Technologies Medalist i3070 Series System Installation

Inline ict system
Hide thumbs Also See for Medalist i3070 Series:
Table of Contents

Advertisement

Uncrating the System

Overview

To uncrate the Medalist i3070 Series 5i system you will need a space
approximately 2.5 m (8 feet) by 4 m (13 feet).
Check for Shipping Damage
Before uncrating the system, check the Tilt and Shock indicators and
notify the carrier if any of them have been triggered.
Tools Required
• Safety glasses
• Gloves
• Utility knife or scissors
• 14 mm (9/16") wrench or socket
Precautions
Only qualified personnel should uncrate the system. A minimum of two people are
WARNING
required.
Avoid injury by following the instructions carefully.
A fully loaded test system with shipping pallet can weigh in excess of 1100 kg (2400 lb)
and should be moved with caution using a forklift. See
The test system is wrapped in plastic wrap. Do not move the crate or the system to a static
CAUTION
sensitive area until you have removed the plastic wrap from the system.
26
Save all packaging materials in case the system is to be reshipped or
NOTE
moved to another site.
Handling
Guidelines.
Medalist i3070 Series 5i System Installation