Service Calibration Period; Standard Link Interface Adapters; Cable Types Tested; Time For Autotest - Fluke CableAnalyzer DTX-1500 Technical Reference Handbook

Hide thumbs Also See for CableAnalyzer DTX-1500:
Table of Contents

Advertisement

DTX-1500 CableAnalyzer
Technical Reference Handbook
Warning
Under no circumstances is this product intended
for direct connection to telephony inputs,
systems, or equipment, including ISDN inputs.
Doing so is a misapplication of this product, which
could result in damage to the tester and create a
potential shock hazard to the user.

Service Calibration Period

One year.

Standard Link Interface Adapters

6A/Class E
channel adapters
A
Plug type and life: shielded 8-pin modular (RJ45);
>5000 insertions
Tests supported: shielded and unshielded cable, TIA Cat
3, 4, 5, 5e, 6, 6A and ISO/IEC Class C, D, E, and E
channels

Cable Types Tested

Shielded and unshielded twisted pair (STP, FTP, SSTP,
and UTP) LAN cabling:
TIA Category 3, 4, 5, 5e, 6, and 6A: 100 
ISO/IEC Class C and D: 100  and 120 
9-10
A
For availability of additional adapters that allow
testing to other performance standards and
different cabling types, contact Fluke Networks.

Time for Autotest

Time for a full, 2-way Autotest of Category 6 UTP cable: 9
seconds

Tone Generator Specifications

Generates tones that can be detected by a tone probe, such
as a Fluke Networks IntelliTone
generated on all pairs.
Frequency range of tones: 440 Hz to 831 Hz

Summary of Performance Specifications

All specifications for tests on twisted pair cabling
apply to 100
cable. Contact Fluke Networks for
information on measurement performance for
cable with a different impedance.
For Category 6/Class E test modes or below, the DTX
CableAnalyzer is compliant with Level III requirements of
TIA-568-C.2-1 and IEC 61935-2.
Note
probe. The tones are
Note

Advertisement

Table of Contents
loading