Taylor-Dunn ET-3000 Manual page 27

Hide thumbs Also See for ET-3000:
Table of Contents

Advertisement

T-48 AC / ET 3000
72-volt equipped with 18:1 drive ratio
Acceleration Parameters (normal mode)
Function
Value Unit Description
FwdAS LS
3.5
FwdAc HS
4.0
6.0
RevAc LS
RevAc HS
6.0
Acceleration Parameters (low speed mode)
FwdAS LS
4.0
FwdAc HS
4.0
RevAc LS
5.0
RevAc HS
7.4
Deceleration Settings
Brake Multiplier
50
Normal Decl HS
9.0
Normal Decl LS
11.0
Tow Decl HS
9.5
Tow Decl LS
11.0
Maintenance Meter Function
Service Timer
0*
Speed Limits
5,400 RPM Governed speed (see formula)
Max (see warning)
Tow
56
Rev
40
35
Low Batt
Service Due
25
Battery Characteristics
2.165
Full Volts
Empty Volts
1.730
BDI Level for Batt Spd
15
BDI Reset %
80
Reset Volts
2.10
Discharge Time
60
Miscellaneous
SRO Min Speed
1,500 RPM
MB-T48-02
Safety Rules and Operating Instructions
S Time to accelerate to ~15% of full
speed
S Time to accelerate to full speed
S Time to accelerate to from FwdAC
LS to full
S Time to accelerate to full speed
S Time to accelerate to ~15% of full
speed
S Time to accelerate to full speed
S Time to accelerate to from FwdAC
LS to full
S Time to accelerate to full speed
% Brake regen multiplier is activated
by the brake switch
S Time to decelerate to 0 when
above 20% of full speed
S Time to decelerate when below
20% of full speed
S Time to decelerate to 0 when
above 20% of full speed
S Time to decelerate when below
20% of full speed
Refer to Maintenance Meter
H
supplementary manual
% Percentage of Max speed when
Tow Switch is ON
% Percentage of Max speed when in
reverse
% Percentage of Max speed when
low battery warning is ON
Percentage Max speed when
%
service is due. See maintenance
Meter Function
V Battery must exceed this voltage
to be considered fully charged
V Voltage of a fully discharged
battery
Low battery warning is ON when
%
battery is discharged below this
level
Battery must be discharged below
%
this value before the BDI will be
allowed to reset
Battery voltage must be above this
value to reset the BDI. Modified
V
by the 'BDI Reset %' above)
M Estimated battery discharge rate
Motor must be below this RPM to
change directions with the throttle
pedal depressed
48-volt equipped with 24:1 drive ratio
Acceleration Parameters (normal mode)
Function
Value Unit Description
FwdAS LS
2.5
FwdAc HS
4.0
RevAc LS
8.0
RevAc HS
7.0
Aceleration Parameters (low speed mode)
FwdAS LS
4.0
FwdAc HS
5.5
RevAc LS
8.0
RevAc HS
7.0
Deceleration Settings
Brake Multiplier
40
Normal Decl HS
8.0
Normal Decl LS
10.0
Tow Decl HS
8.5
Tow Decl LS
8.0
Maintenance Meter Function
Service Timer
0
Speed Limits
Max (see warning)
5,500 RPM Governed speed (see formula)
Tow
60
Rev
45
Low Batt
40
20
Service Due
Battery Characteristics
Full Volts
2.105
1.730
Empty Volts
BDI Level for Batt Spd
15
BDI Reset %
80
Reset Volts
2.10
Discharge Time
60
Miscellaneous
SRO Min Speed
1,500 RPM
Time to accelerate to ~15% of full
S
speed
S
Time to accelerate to full speed
Time to accelerate to from FwdAC
S
LS to full
S
Time to accelerate to full speed
Time to accelerate to ~15% of full
S
speed
S
Time to accelerate to full speed
Time to accelerate to from FwdAC
S
LS to full
S
Time to accelerate to full speed
% Brake regen multiplier is activated
by the brake switch
Time to decelerate to 0 when above
S
20% of full speed
Time to decelerate when below
S
20% of full speed
Time to decelerate to 0 when above
S
20% of full speed
Time to decelerate when below
S
20% of full speed
Refer to Maintenance Meter
H
supplementary manual
% Percentage of Max speed when
Tow Switch is ON
% Percentage of Max speed when in
reverse
% Percentage of Max speed when low
battery warning is ON
Percentage of Max speed when
%
service is due. See maintenance
Meter Function
V Battery must exceed this voltage to
be considered fully charged
V Voltage of a fully discharged bat-
tery
Low battery warning is ON when
%
battery is discharged below this
level
Battery must be discharged below
%
this value before the BDI will be
allowed to reset
Battery voltage must be above this
value to reset the BDI. Modified by
V
the 'BDI Reset %' above)
M Estimated battery discharge rate
Motor must be below this RPM to
change directions with the throttle
pedal depressed
Page 13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

T-4B0-t48-48acB0-t48-72acEt-030-48ac