Siemens SIMATIC ET 200SP Manual page 36

Technology module, tm count 1x24v
Hide thumbs Also See for SIMATIC ET 200SP:
Table of Contents

Advertisement

Filter frequency
for counter inputs
Sensor type
Signal selection for reference
mark 0
Measuring input
Encoder type
Increments per revolution /
steps per revolution
Reference speed
Distance between increments
Fine-resolution increment dis-
tance
Reference velocity
Enable diagnostic interrupt on
wire break
Enable additional diagnostic
interrupts
Explanation of parameters
You can find a detailed description of the parameters in function manual Counting,
Measurement and Position Detection, section Module parameters (position input for Motion
Control) available for download on the Internet
(http://support.automation.siemens.com/WW/view/en/59709820).
TM Count 1x24V (6ES7138‑6AA01‑0BA0) technology module
Manual, 07/2019, A5E33002339-AD
Parameter
DI1
1...65535
6.00...3000.00...210000.00 U/min
250...16000...25000000
Automatically calculated (read-only)
0.60...16.00...600.00 m/min
4.2 Position input for ""Motion Control"" technology object
Value range
100 Hz
200 Hz
500 Hz
1 kHz
2 kHz
5 kHz
10 kHz
20 kHz
50 kHz
100 kHz
200 kHz
Sourcing output
Sinking output
Push-pull (sinking and sourcing output)
DI0
Signal N of incremental encoder
Linear
Rotary
Deactivated
Activated
Deactivated
Activated
Configuring/address space
Scope
Channel
Channel
Channel
Channel
Channel
Channel
Channel
Channel
Channel
Channel
Channel
Channel
35