Drive-Cliq Encoder; Description - Siemens SINAMICS S120 Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Figure 9-55
Max. cable length as a function of the current drawn by the encoder system
In addition to the encoder systems for the supply voltage range of 4.75 V to 5.25 V in the diagram
above, encoder systems are also available for the extended range down to 3.6 V. These are
generally operable using encoder system cables up to 30 m in length, provided that the total
cross-section of the supply plus Remote Sense wires does not fall below 0.14 mm².
9.12

DRIVE-CLiQ encoder

9.12.1

Description

The DRIVE-CLiQ encoder is available as an absolute encoder with integrated DRIVE-CLiQ
interface. The multiturn design of the encoder senses absolute position values extending over
4096 revolutions. The single-turn design senses the absolute position within a revolution.
The most important advantages are:
• Automatic commissioning via DRIVE-CLiQ
• High operating temperatures of 100 °C are possible
Control Units and additional system components
Equipment Manual, 06/2020, 6SL3097-5AH00-0BP2
Encoder system connection
9.12 DRIVE-CLiQ encoder