The following table describes the Status Byte Register.
Bit
Name
Decimal
0
Not Used
1
1
Not Used
2
2
Error
4
Queue
3
Extended
8
Event
4
Message
16
Available
5
Standard
32
Event
6
Request
64
Service
7
Not Used
128
212
GlobalTestSupply
www.
T3PM1100 User Manual
Definition
(Reserved for future use)
(Reserved for future use)
One or more errors have been stored in the
Error Queue. Use STAT:ERR? to read and
delete errors.
One or more bits are set in the Extended
Event Register (bits must be enabled, see
STAT:EESE).
Data is available in the instrument's output
buffer.
One or more bits are set in the Standard
Event Register (bits must be enabled, see
*ESE).
One or more bits are set in the Status Byte
Register and may generate a Request for
Service (RQS). Bits must be enabled using
*SRE.
(Reserved for future use)