Find Quality Products Online at:
Return parameter 0
1
Example
: HARMONICS:DISPLAY:STATE OFF
: HARMONICS:DISPLAY:STATE?
->:HARMONICS:DISPLAY:STATE 0
:HARMonics:DISPlay:ORDer
Sets or returns the harmonic order of the
Description
harmonic component that is shown in graph-
>hormoics->bar page for the harmonic
measurement data display.
Syntax
:HARMonics:DISPlay:ORDer {<NR1>}
Query Syntax
:HARMonics:DISPlay:ORDer?
Parameter/
<NR1>
Return parameter
Example
:HARMONICS:DISPLAY:ORDER 1
:HARMONICS:DISPLAY:ORDER?
->:HARMONICS:DISPLAY:ORDER 1
:HARMonics:PLLSource
Sets or returns the PLL source.
Description
Syntax
:HARMonics:PLLSource {U1|I1}
Query Syntax
:HARMonics:PLLSource?
Parameter/
U1
Return parameter
I1
Example
:HARMONICS:PLLSOURCE U1
:HARMONICS:PLLSOURCE?
->:HARMONICS:PLLSOURCE U1
142
GlobalTestSupply
www.
T3PM1100 User Manual
Turn the harmonic display off.
Turn the harmonic display on.
Set
Query
1 to 50 (harmonic order).
Set
Query
Select pll source at voltage.
Select pll source at current.
.com