Communicate:lockout; Communicate:remote - Teledyne T3PM1100 User Manual

Digital power meter
Hide thumbs Also See for T3PM1100:
Table of Contents

Advertisement

Find Quality Products Online at:
Example of a response with a header
Note
:INPUT:VOLTAGE:RANGE 150.0E+00
Example of a response without a header
150.0E+00

:COMMunicate:LOCKout

Sets or returns local lockout.
Description
Syntax
:COMMunicate:LOCKout {<Boolean>|OFF | ON}
Query Syntax
:COMMunicate:LOCKout?
Parameter
<Boolean>0 OFF
<Boolean>1 ON
Return parameter 0
1
Example
:COMMUNICATE:LOCKOUT ON
:COMMUNICATE:LOCKOUT?
-> :COMMUNICATE:LOCKOUT 1

:COMMunicate:REMote

Sets or returns the T3PM1100 to remote or local
Description
mode. ON is remote mode.
Syntax
:COMMunicate:REMote {<Boolean>|OFF | ON}
Query Syntax
:COMMunicate:REMote?
Parameter
<Boolean>0 OFF
<Boolean>1 ON
Return parameter 0
1