Integrate:function; Integrate:timer; Integrate:start - Teledyne T3PM1100 User Manual

Digital power meter
Hide thumbs Also See for T3PM1100:
Table of Contents

Advertisement

Find Quality Products Online at:

:INTEGrate:FUNCtion

Sets or returns the integration function.
Description
Syntax
:INTEGrate:FUNCtion {WATT|AMPEre}
Query Syntax
:INTEGrate:FUNCtion?
Parameter/
WATT
Return parameter
AMPEre
Example
:INTEGRATE:FUNCTION WATT
:INTEGRATE:FUNCTION?
->:INTEGRATE:FUNCTION WATT

:INTEGrate:TIMer

Sets or returns the integration timer value.
Description
Syntax
:INTEGrate:TIMer {<NRf>,<NRf>,<NRf>}
Query Syntax
:INTEGrate:TIMer?
Parameter/
1st <NRf>
Return parameter
2nd <NRf>
3rd <NRf>
Example
:INTEGRATE:TIMER 1,0,0
:INTEGRATE:TIMER?
->:INTEGRATE:TIMER 1,0,0

:INTEGrate:STARt

Starts integration.
Description
Syntax
:INTEGrate:STARt
Example
:INTEGRATE:START
GlobalTestSupply
www.
COMMAND OVERVIEW
Set
Query
Select the integration function watt.
Select the integration function ampere.
Set
Query
0 to 9999 (hours)
0 to 59 (minutes)
0 to 59 (seconds)
Set
.com
159
sales@GlobalTestSupply.com

Advertisement

Table of Contents
loading

Table of Contents