8.2 I/O Number Allocation
I/O number
CH0 CH1 CH2 CH3 CH4 CH5 CH6 CH7
X13
X33
X53
X14
X34
X54
X15
X35
X55
X16
X36
X56
to
to
to
X1E
X3E
X5E
X1F
X3F
X5F
(Note 1)
The I/O numbers in the table indicate offset addresses. The I/O numbers actually allocated are the
numbers based on the starting word number allocated to the unit.
Example) When the starting word number for the unit is "10", the error flag is X11F, the disconnection
detection execution relay of CH0 is Y100, and the error flag reset relay is Y10F.
(Note 2)
For the Thermocouple Multi-analog Input Unit, the disconnection detection function is valid in the case
of the following range; "Thermocouple, voltage: 1-5 V and current: 4-20 mA".
(Note 3)
On the RTD input unit (AFP7RTD8), the disconnection detection execution relay and the
disconnection detection flag cannot be used. Disconnection is detected by a digital value (K30000)
different from normally converted values within the range.
Output flag
I/O number
CH0 CH1 CH2 CH3 CH4 CH5 CH6 CH7
Y0
Y10
Y20
Y1
Y11
Y21
Y2
Y12
Y22
Y3
Y13
Y23
Y4
Y14
Y24
Y5
Y15
Y25
Y6
Y16
Y26
8-8
X13
X73
X93
X113
3
X13
X74
X99
X114
4
X13
X75
X95
X115
5
X13
X116
X76
X96
6
to
to
to
to
X11
X7E
X9E
X13
E
E
X11
X13
X7F
X9F
F
F
Y30
Y40
Y50
Y60
Y31
Y41
Y51
Y61
Y32
Y42
Y52
Y62
Y33
Y43
Y53
Y63
Y34
Y44
Y54
Y64
Y35
Y45
Y55
Y65
Y36
Y46
Y56
Y66
Name
Upper/Lower limit
X15
Comparison
3
execution flag
X15
Not used
4
Max./Min.
X15
Hold execution
5
flag
X15
6
Not used
to
X15
E
X15
Error flag
F
Name
Disconnection
detection
execution
Y70
(Note 2)(Note
relay
3)
Y71
Not used
Y72
Upper/Lower limit
Y73
Comparison
execution relay
Y74
Not used
Max./Min.
Y75
Hold execution
relay
Y76
Not used
Description
Turns ON when the upper limit/lower
limit comparison function is
executed.
Do not use.
Turns ON when the max./min. hold
function is executed.
Do not use.
Turns ON when an error occurs
Description
ON to execute the disconnection
detection function.
OFF to turn OFF the disconnection
detection flag (Xn0).
Do not use.
ON to execute the function to
compare the upper and lower limits.
OFF to turn OFF the upper limit
comparison relay (Xn1) and lower
limit comparison relay (Xn2).
Do not use.
ON to execute the max./min. hold
function.
Do not use.
WUME-FP7TCRTD-04