4.1 Confirming the I/O Number Allocations and Starting Word Number
Input contact (Optional functions/Error flag area)
I/O number
CH0 CH1 CH2 CH3 CH4 CH5 CH6 CH7
X10
X30
X50
X11
X31
X51
X12
X32
X52
X13
X33
X53
X14
X34
X54
X15
X35
X55
X16
X36
X56
to
to
to
X1E
X3E
X5E
X1F
X3F
X5F
(Note 1)
The I/O numbers in the table indicate offset addresses. The I/O numbers actually allocated are the
numbers based on the starting word number allocated to the unit.
Example) When the starting word number for the unit is "10", the error flag is X11F, the disconnection
detection execution relay of CH0 is Y100, and the error flag reset relay is Y10F.
(Note 2)
For the Thermocouple Multi-analog Input Unit, the disconnection detection function is valid in the case
of the following range; "Thermocouple, voltage: 1-5 V and current: 4-20 mA".
(Note 3)
On the RTD input unit (AFP7RTD8), the disconnection detection execution relay and the
disconnection detection flag cannot be used. Disconnection is detected by a digital value (K30000)
different from normally converted values within the range.
Output flag
I/O number
CH0 CH1 CH2 CH3 CH4 CH5 CH6 CH7
Y0
Y10
Y20
Y1
Y11
Y21
Y2
Y12
Y22
Y3
Y13
Y23
WUME-FP7TCRTD-04
X13
X70
X90
X110
0
X13
X71
X91
X111
1
X13
X72
X92
X112
2
X13
X73
X93
X113
3
X13
X74
X99
X114
4
X13
X75
X95
X115
5
X13
X116
X76
X96
6
to
to
to
to
X11
X7E
X9E
X13
E
E
X11
X13
X7F
X9F
F
F
Y30
Y40
Y50
Y60
Y31
Y41
Y51
Y61
Y32
Y42
Y52
Y62
Y33
Y43
Y53
Y63
Name
Disconnection
X15
detection
0
(Note 2)(Note 3)
flag
X15
Upper limit
1
comparison relay
X15
Lower limit
2
comparison relay
Upper/Lower limit
X15
Comparison
3
execution flag
X15
Not used
4
Max./Min.
X15
Hold execution
5
flag
X15
6
Not used
to
X15
E
X15
Error flag
F
Name
Disconnection
detection
execution
Y70
(Note 2)(Note
relay
3)
Y71
Not used
Y72
Y73
Upper/Lower limit
Description
ON with disconnection detected and
OFF with disconnection restored.
Turns ON when the value exceeds
the set upper limit.
Turns OFF when the value drops
below the set lower limit.
Turns ON when the upper limit/lower
limit comparison function is
executed.
Do not use.
Turns ON when the max./min. hold
function is executed.
Do not use.
Turns ON when an error occurs
Description
ON to execute the disconnection
detection function.
OFF to turn OFF the disconnection
detection flag (Xn0).
Do not use.
ON to execute the function to
compare the upper and lower limits.
4-3

Advertisement