Time Average; Moving Average - Panasonic FP7 Series User Manual

Programmable controller thermocouple multi-analog input unit / rtd input unit
Hide thumbs Also See for FP7 Series:
Table of Contents

Advertisement

6.1.2 Time Average

Overview of functions
● Analog input data sampled by the unit is averaged and stored as digital values.
● If "time average" is set, analog input data items acquired will be stored in unit memory (UM)
as digital values when the acquisition period of the analog input data items reaches the set
averaging time.
● Obtain the time average to be processed from the following input.
Input
The sum of analog input data items for the number of averaging time.
Output
Time average value
Processing during time average
Average setting example: "time average", averaging time of 200 msec
A0
Analog signal
Analog input
processing
Analog input
data
Configuration
Name
Average processing
Function
setting
Averaging constant

6.1.3 Moving Average

Overview of functions
● Analog input data sampled by the unit is averaged and stored as digital values.
WUME-FP7TCRTD-04
Elapse of
200 msec
A2
A1
・・・・・
・・・・・
Average of A0 to An
Default
Not execute
U200
6.1 Average Processing Settings
Elapse of
200 msec
An
B0
B1
B2
・・・・・
・・・・・
Setting range and description
Select "time average".
Time: 200 to 60000 [ms] (specified with an unsigned
integer)
C1
C0
C2
Bn
Average of B0 to Bn
・・・・・
・・・・・