Service Manual
Panel Plate X430
1. Turn off the air conditioner and the circuit breaker.
2. Remove the screw of the big handle and then remove the big handle (1
screw).
Figure 108
3. Remove the screws of the top cover and then remove the top cover (3
screws). One of the screws is located underneath the big handle.
Top Cover
Figure 109
4. Remove the screws of water collecting cover and then remove the water
collecting cover (2 screws).
Figure 110
5. Remove the screws of the front panel and then remove the front panel (7
8 0 |
Big Handle
Water Collecting
Cover
Bosch Wall Mounted Ductless Split Air Conditioner / Heat Pump IDU-ODU - BTC 769102301 A (11.2022)
screws(onoff models) or 9 screws(inverter models).
Front Panel
Figure 111
6. Remove the screws of the right panel and then remove the right panel (6
screws).