Bosch Climate 5000 Series Service Manual page 31

Wall mounted ductless split air conditioner/ heat pump
Hide thumbs Also See for Climate 5000 Series:
Table of Contents

Advertisement

7.3.3 PCB: Max Performance Single Zone 18K
BMS500-AAS018-1CSXHC
Figure 25
Number
Name
1
Power Supply (CN3)
2
S
3
4-WAY
4
HEAT1
5
AC-FAN
6
HEAT2
7
PMV
8
T5 T4 T3
9
DC-FAN
10
TESTPORT
11
FAN_IPM
12
EE_PORT
U
13
V
W
14
COMP_IPM
Table 17
Bosch Wall Mounted Ductless Split Air Conditioner / Heat Pump IDU-ODU - BTC 769102301 A (11.2022)
CN#
Description
CN6
Earth: connect to Ground
CN7
N_in: connect to N-line (208-230V AC input)
CN8
L_in: connect to L-line (208-230V AC input)
CN2
S: connect to indoor unit communication
CN60
connect to 4 way valve, 208-230V AC when is ON.
CN16
connect to compressor heater, 208-230V AC when is ON
CN5
connect to AC fan
CN19
connect to chassis heater, 208-230V AC when is ON
CN18
connect to Electric Expansion Valve
CN17
connect to pipe temp. sensor T3, ambient temp. sensor T4, exhaust temp. sensor T5
CN41
connect to DC fan
CN6
used for testing
IPM2
IPM for DC fan
CN505
EEPROM programmer port
CN28
connect to compressor
CN29
0V AC (standby)
CN30
10-200V AC (running)
IPM 301
IPM for compressor
Service Manual
| 31

Advertisement

Table of Contents
loading

Table of Contents