Bosch Climate 5000 Series Service Manual page 48

Wall mounted ductless split air conditioner/ heat pump
Hide thumbs Also See for Climate 5000 Series:
Table of Contents

Advertisement

Service Manual
Index 1:
1. Indoor or Outdoor DC Fan Motor (control chip is in fan motor)
Power on and when the unit is in standby, measure the voltage of pin1-pin3,
pin4-pin3 in fan motor connector. If the value of the voltage is not in the
range showing in below table, the PCB must have problems and needs to be
replaced.
1
2
3
Red
Black
Figure 42
DC motor voltage input and output (voltage: 220-240V~)
NO.
Color
1
Red
2
---
3
Black
4
White
5
Yellow
6
Blue
Table 25
DC motor voltage input and output (voltage :115V~)
NO.
Color
1
Red
2
---
3
Black
4
White
5
Yellow
6
Blue
Table 26
2. Outdoor DC Fan Motor (control chip is in outdoor PCB)
Release the UVW connector. Measure the resistance of U-V, U-W and V-W. If
the three values are not equal, the fan motor has a problem and needs to be
replaced.
Otherwise, replace the ODU PCB.
4 8 |
4
5
6
White Yellow
Blue
Signal
Voltage
Vs/Vm
280V~380V
---
---
GND
0V
Vcc
14-17.5V
Vsp
0~5.6V
FG
14-17.5V
Signal
Voltage
Vs/Vm
140V~190V
---
---
GND
0V
Vcc
14-17.5V
Vsp
0~5.6V
FG
14-17.5V
Bosch Wall Mounted Ductless Split Air Conditioner / Heat Pump IDU-ODU - BTC 769102301 A (11.2022)
3. Indoor AC Fan Motor
a. Power off and disconnect fan motor power cord from PCB. Measure the
resistance value of each winding by using the multi-meter. The normal
value show as follows:
YKFG-13-4-38L
Model
YKFG-13-4-
38L-4
Brand
Welling
Black - Red Main
345Ω
Blue - Black AUX
348Ω
Table 27
YKFG-20-4-
Model
5-19
Brand
Welling
Black - Red Main
444Ω
Blue - Black AUX
470Ω
Table 28
YKFG-45-4-22
Model
YKFG-45-4-13
Brand
Dongfang
Black - Red Main
125.2Ω
Blue - Black AUX
83.8Ω
Table 29
Model
Brand
Black - Red Main
Blue - Black AUX
Table 30
b. Power on and set the unit running in fan mode at high fan speed. After
running for 15 seconds, measure the voltage of pin1 and pin2. If the
value of the voltage is less than 1 OOV(208-240V power supply) or
50V (115V power supply), the PCB must has problems and need to be
replaced.
Input Terminal
Red
Black
White
Figure 43
YKFG-15-4-
YKFG-20-4-
YKFG-20-4-
28-1
1 0L
5-11
Welling
Welling
Welling
75Ω
269Ω
388Ω
150Ω
224Ω
360Ω
YKFG-28-4-3-7
YKFG-25-4-
YKFG-28-
YKFG-28-4-
6-14
4-6-5
3-14
Welling
Welling
Welling
287Ω
231Ω
183.6Ω
409Ω
414Ω
206Ω
YKFG-60-4-2-6
YKFG-60-4-1
YKFG-45-4-
22-13
Welling
Welling
Welling
168Ω
96Ω
68Ω
141Ω
96Ω
53Ω
YKFG-45-4-13
Dongfang
450Ω
442Ω
Red
White
Black

Advertisement

Table of Contents
loading

Table of Contents