4. Remove the bearing sleeve.
Figure 86
5. Remove the fi xing screw.
6. Pull out the fan motor and fan assembly from the side.
7 4 |
Bosch Wall Mounted Ductless Split Air Conditioner / Heat Pump IDU-ODU - BTC 769102301 A (11.2022)
8.1.4 Step Motor
    R emove the front panel and chassis assembly (refer to 9.1.1 Front
Panel and 9.1.3 Fan Motor and Fan) before disassembling step motor.
1. Remove one screw to remove cover of louver motor (for some units).
Figure 87
2. Open the cover of louver motor, pull out intelligent eye subassembly.
Figure 88
3. Remove the two screws, then remove the horizontal swing motor (see Figure
143).
    T he horizontal swing motor is located in panel assembly.