Omron JX Series Replacing Manual page 29

Simple, compact inverters
Table of Contents

Advertisement

Multi-function input 1
1103h
selection
2nd multi-function input 1
1532h
selection
Multi-function input 2
1104h
selection
2nd multi-function input 2
1533h
selection
Multi-function input 3
1105h
selection
2nd multi-function input 3
1534h
selection
Multi-function input 4
1106h
selection
2nd multi-function input 4
1535h
selection
Multi-function input 5
1107h
selection
2nd multi-function input 5
1536h
selection
Multi-function input 1
110Bh
Multi-function input 2
110Ch
Multi-function input 3
110Dh
Multi-function input 4
110Eh
Multi-function input 5
110Fh
00: FW
01: RV
02: CF1
C001
03: CF2
04:CF3
05: CF4
06: JG
07: DB
08: SET
09: 2CH
C201
11: FRS
12: EXT
13: USP
15: SFT
16: AT
18: RS
19: PTC terminal 5 only
C002
20: STA
2+1: STP
22: F/R
23: PID
24: PIDC
27: UP
28: DWN
C202
29: UDC
31: OPE
50: ADD
51: F-TM
52: RDY
53: SP-SET
64: EMR(automatically allocated to
C003
terminal 3 if enabled)
255: NO
C203
C004
C204
C005
C205
C011
C012
00︓NO
C013
01︓NC
C014
C015
1401h
C001
1402h
C002
1403h
C003
-
1404h
C004
1405h
C005
140Bh
C011
140Ch
C012
-
140Dh
C013
140Eh
C014
140Fh
C015
29
00: FW (Forward)
01: RV (Reverse)
02: CF1 (Multi-step speed setting
binary 1)
03: CF2 (Multi-step speed setting
binary 2)
04: CF3 (Multi-step speed setting
binary 3)
05: CF4 (Multi-step speed setting
binary 4)
06: JG (Jogging)
07: DB (External DC injection
braking)
08: SET (2nd control)
09: 2CH (2-step
acceleration/deceleration)
11: FRS (Free-run stop)
12: EXT (External trip)
13: USP (Power recovery restart
prevention function)
14: CS (Commercial switch)
15: SFT (Soft lock)
16: AT (Analog input switching)
18: RS (reset)
19: TH (PTC thermistor thermal
protection)
<C005 only>
20: STA (3-wire start)
21: STP (3-wire stop)
22: F/R (3-wire forward/reverse)
23: PID (PID disabled)
24: PIDC (PID integral reset)
27: UP (Remote operation
accelerated)
28: DWN (Remote operation
decelerated)
29: UDC (Remote operation data
clear)
31: OPE (Forced operator function)
32: SF1 (Multi-step speed setting bit
1)
33: SF2 (Multi-step speed setting bit
2)
34: SF3 (Multi-step speed setting bit
3)
35: SF4 (Multi-step speed setting bit
4)
36: SF5 (Multi-step speed setting bit
5)
37: SF6 (Multi-step speed setting bit
6)
38: SF7 (Multi-step speed setting bit
7)
39: OLR (Overload limit switching)
40: TL (Torque limit enabled)
41: TRQ1 (Torque limit switching 1)
42: TRQ2 (Torque limit switching 2)
44: BOK (Brake confirmation)
46: LAC (LAD cancel)
47: PCLR (Current position clear)
50: ADD (Set frequency A145
addition)
51: F-TM (Forced terminal block)
52: ATR (Torque reference input
permission)
53: KHC (Integrated power clear)
56: MI1 (General-purpose input 1)
57: MI2 (General-purpose input 2)
58: MI3 (General-purpose input 3)
00: NO (NO contact)
01: NC (NC contact)
-
-