FI start selection
1085h
Operation frequency input A
108Eh
setting
Operation frequency input B
108Fh
setting
Operator selection
1090h
Frequency addition amount
1091h
Frequency addition direction
1093h
VR start frequency
1095h
VR end frequency
1097h
VR start ratio
1098h
VR end ratio
1099h
VR start selection
109Ah
Retry selection
10A5h
Allowable momentary power
10A6h
Retry wait time
10A7h
Momentary power
interruption/undervoltage
10A8h
trip during stop selection
Momentary power
10A9h
interruption retry time
Starting frequency at
1170h
frequency pull-in restart
Electronic thermal level
10ADh
2nd electronic thermal level
1527h
Electronic thermal
10AEh
characteristics selection
2nd electronic thermal
1528h
characteristics selection
Overload limit selection
10B5h
2nd overload limit selection
1529h
Overload limit level
10B6h
2nd overload limit level
152Ah
Overload limit parameter
10B7h
2nd overload limit parameter 152Bh
Deceleration rate constant
1171h
Frequency pull-in restart
1172h
Soft lock selection
10BCh
Selection of non-stop
function at momentary
10C9h
power interruption
Starting voltage of non-stop
function at momentary
10CAh
power interruption
Stop deceleration level of
non-stop function at
10CBh
momentary power
interruption
Deceleration time of nonstop
10CCh
function at momentary
Deceleration starting width
of non-stop function at
10CEh
momentary power
interruption
Overvoltage protection
proportional gain during
1173h
deceleration
Overvoltage protection
integral time during
1174h
deceleration
00: Start frequency A101
A105
01: 0 Hz
00: Digital Operator (F001)
01: Digital Operator (volume)
A141
02: Input FV
03: Input FI
04: RS485 communications
A142
00: Addition (A + B)
A143
01: Subtraction (A − B)
02: Multiplication (A × B)
A145
0 ~ 4000
00: Adds the A145 value to the
A146
output
A151
0 ~ 4000
A152
0 ~ 4000
A153
0 ~ 100
A154
0 ~ 100
A155
0, 1
00: Alarm
01: 0 Hz start
02: Frequency matching restart
b001
03: Trip after frequency matching
deceleration stop
b002
3 ~ 250
b003
3 ~ 1000
00: Disabled
01: Enabled
b004
00: 16 times
b005
01: No limit
00: Frequency at interruption
b011
01: Max. frequency
02: Set frequency
b012
2000 to 10000
b212
Set the rated current to 10000
b013
00: Reduced torque characteristics 1
01: Constant torque characteristics
b213
02: Reduced torque characteristics 2
b021
00: Disabled
b221
01: Enabled in acceleration/constant
b022
00: Disabled
b222
01: Enabled in acceleration/constant
b023
1 ~ 300
b223
b029
1 ~ 30000
b030
200 ~ 20000
00: Data other than b031 cannot be
changed when terminal SFT is ON.
01: Data other than b031 and the
specified frequency parameter
cannot be changed when terminal
SFT is ON.
02: Data other than b031 cannot be
b031
changed.
03: Data other than b031 and the
specified frequency parameter
cannot be changed.
10: Data other than parameters
changeable during operation cannot
be changed.
00: Disabled
b050
01: Enabled (Stop)
02: Enabled (Restart)
b051
0 ~ 10000
b052
0 ~ 10000
b053
1 ~ 30000
b054
0 ~ 100
b055
2 ~ 50
b056
0 ~ 1500
-
1287h
A105
12AFh
A141
-
12B0h
A142
-
12B1h
A143
12B3h A145(HIGH)
0.1[Hz]
12B4h
A145(LOW)
-
12B5h
A146
12C6h A161(HIGH)
0.1[Hz]
12C7h
A161(LOW)
12C8h A162(HIGH)
0.1[Hz]
12C9h
A162(LOW)
1[%]
12CAh
A163
1[%]
12CBh
A164
-
12CCh
A165
-
1301h
b001
0.1[s]
1302h
b002
0.1[s]
1303h
b003
-
1304h
b004
-
1305h
b005
-
131Fh
b030
130Dh
b012
0.01[%]
230Ch
b212
130Eh
b013
-
230Dh
b213
1316h
b021
-
2316h
b221
1317h
b022
0.01[%]
2317h
b222
1318h
b023
0.1[s]
2318h
b223
0.1[s]
131Eh
b029
0.01[%]
131Dh
b028
-
1320h
b031
-
1334h
b050
0.1[V]
1335h
b051
0.1[V]
1336h
b052
1337h
b053(HIGH)
0.1[s]
1338h
b053(LOW)
0.1[Hz]
1339h
b054
0.1
1388h
b133
0.1[s]
1389h
b134
27
00: FI Start Frequency (A101)
01: 0 Hz
00: Digital Operator (A020/A220)
01: Volume
02: Voltage (FV) input
03: Current (FI) input
04: Modbus communication
05: Option
07: Pulse train frequency
00: Addition (A141 + A142)
01: Subtraction (A141 − A142)
02: Multiplication (A141 × A142)
0~40000 (In the high-frequency
mode︓~58000)
00: Frequency reference + A145
01: Frequency reference − A145
0~40000 (In the high-frequency
mode︓~58000)
0~40000 (In the high-frequency
mode︓~58000)
0 to VR End Ratio
VR Start Ratio to 100
00: VR Start Frequency (A161)
01: 0 Hz
00: Trip
01: 0-Hz restart
02: Frequency matching restart
03: Trip after frequency matching
deceleration stop
04: Frequency pull-in restart
3~250
3~1000
00: Disabled
01: Enabled
02: Disabled during stop and
deceleration stop by turning off the
RUN command
00: 16 times
01: No limit
00: Frequency at interruption
01: Maximum frequency
02: Set frequency (Frequency
reference)
200~1000
00: Reduced torque characteristics
01: Constant torque characteristics
02: Free setting
00: Disabled
01: Enabled during
200~2000
1~30000
1~30000
200~2000
00: Data other than b031 cannot be
changed when terminal SFT is ON.
01: Data other than b031 and the
set frequency cannot be changed
when terminal SFT is ON.
02: Data other than b031 cannot be
changed.
03: Data other than b031 and set
frequency cannot be changed.
10: Data can be changed during
RUN.
00: Disabled
01: Enabled (Deceleration stop)
02: Enabled (Constant voltage,
without recovery)
03: Enabled (Constant voltage, with
recovery)
0~10000
0~10000
1~360000
0~1000 (In the high-frequency
mode︓10000)
0~500
0~1500
-
-
-
0.01[Hz]
-
0.01[Hz]
0.01[Hz]
1[%]
1[%]
-
-
0.1[s]
0.1[s]
-
-
-
0.1[%]
-
-
0.1[%]
0.1[s]
0.1[s]
0.1[%]
-
-
0.1[V]
0.1[V]
0.01[s]
0.01[Hz]
0.01
0.1[s]