Omron JX Series Replacing Manual page 26

Simple, compact inverters
Table of Contents

Advertisement

Output voltage gain
104Eh
2nd output voltage gain
1514h
DC injection braking
1051h
selection
DC injection braking
1052h
frequency
DC injection braking delay
1053h
time
DC injection braking power
1054h
DC injection braking time
1055h
DC injection braking method
1056h
selection
Frequency upper limit
105Ah
2nd frequency upper limit
1517h
Frequency lower limit
105Bh
2nd frequency lower limit
1518h
Jump frequency 1
105Dh
Jump frequency 2
1060h
Jump frequency 3
1063h
Jump frequency width 1
105Eh
Jump frequency width 2
1061h
Jump frequency width 3
1064h
PID selection
1068h
PID P gain
1069h
PID I gain
106Ah
PID D gain
106Bh
PID scale
106Ch
PID feedback selection
106Dh
Reverse PID function
106Eh
PID output limit function
106Fh
AVR selection
1070h
AVR voltage selection
1071h
RUN mode selection
1072h
Energy-saving response/
1073h
1074h
Acceleration time 2
1075h
1519h
2nd acceleration time 2
151Ah
1076h
Deceleration time 2
1077h
151Bh
2nd deceleration time 2
151Ch
2-step acceleration/
1078h
deceleration selection
2nd 2-step acceleration/
151Dh
deceleration selection
2-step acceleration
107Ah
frequency
2nd 2-step acceleration
151Fh
frequency
2-step deceleration
107Ch
frequency
2nd 2-step deceleration
1521h
frequency
Acceleration pattern
107Dh
selection
Deceleration pattern
107Eh
selection
FI start frequency
1080h
FI end frequency
1082h
FI start ratio
1083h
FI end ratio
1084h
A045
20 ~ 100
A245
00: Disabled
A051
01: Enabled during stop
02: Output frequency<A052 DB
A052
0 ~ 600
A053
0 ~ 50
A054
0 ~ 100
A055
0 ~ 600
00: Edge operation
A056
01: Level operation
0.0/Frequency lower limit
A061
: A062 x 10 to Maximum frequency
: A004 x 10
0.0/2nd frequency lower limit
A261
: A262 x 10 to 2nd max. frequency
: A204 x 10
0.0/Starting frequency
A062
: b082 × 10 to Frequency upper
limit: A061 × 10
0.0/Starting frequency
A262
: b082 x 10 to 2nd frequency upper
limit: A261x10
A063
A065
0 ~ 4000
A067
A064
0 ~ 100
A066
A068
00: Disabled
A071
01: Enabled
A072
2 ~ 50
A073
0 ~ 1500
A074
0 ~ 1000
A075
1 ~ 9999
00: Feedback (FI)
01: Feedback (FV)
A076
02: External communication
10: Operation function output
00: OFF (Deviation = Target value -
Feedback value)
A077
01: ON (Deviation = Feedback value
- Target value)
A078
0 ~ 1000
00: Always ON
A081
01: Always OFF
02: OFF during deceleration
200-V class
0: 200/ 1: 215/ 2: 220/ 3: 230/ 4:
240
A082
400-V class
0: 380/ 1: 400/ 2: 415/ 3: 440/ 4:
460/ 5: 480
00: Normal operation
A085
01: Energy-saving operation
A086
0 ~ 1000
A092(MSB
A092(LSB)
1 to 300000
A292(MSB
The second decimal place is ignored
A292(LSB)
when the value is over 10000 (100.0
A093(MSB
A093(LSB)
seconds).
A293(MSB
A293(LSB)
A094
00: Switched via terminal 2CH
01: Switched by setting
A294
A095
A295
0 ~ 4000
A096
A296
A097
00: Line
01: S-shape curve
A098
A101
0 ~ 4000
A102
A103
0 ~ 100
A104
123Fh
A045
1[%]
223Fh
A245
-
1245h
A051
0.1[Hz]
1246h
A052
0.1[s]
1247h
A053
1[%]
1248h
A054
0.1[s]
1249h
A055
-
124Ah
A056
124Fh A061(HIGH)
1250h
A061(LOW)
224Fh A261(HIGH)
2250h
A261(LOW)
0.1[Hz]
1251h A062(HIGH)
1252h
A062(LOW)
2251h A262(HIGH)
2252h
A262(LOW)
1253h A063(HIGH)
1254h
A063(LOW)
1256h A065(HIGH)
0.1[Hz]
1257h
A065(LOW)
1259h A067(HIGH)
125Ah
A067(LOW)
1255h
A064
0.1[Hz]
1258h
A066
125Bh
A068
-
125Fh
A071
0.1
1260h
A072
0.1[s]
1261h
A073
0.1[s]
1262h
A074
0.01
1263h
A075
-
1264h
A076
-
1265h
A077
0.1[%]
1266h
A078
-
1269h
A081
-
126Ah
A082
-
126Dh
A085
0.1[%]
126Eh
A086
1274h A092(HIGH)
1275h
A092(LOW)
226Fh A292(HIGH)
2270h
A292(LOW)
0.01 [s]
1276h A093(HIGH)
1277h
A093(LOW)
2271h A293(HIGH)
2272h
A293(LOW)
1278h
A094
-
2273h
A294
1279h A095(HIGH)
127Ah A095(LOW)
2274h A295(HIGH)
2275h A295(LOW)
0.1[Hz]
127Bh A096(HIGH)
127Ch A096(LOW)
2276h A296(HIGH)
2277h A296(LOW)
127Dh
A097
-
127Eh
A098
1281h A101(HIGH)
1282h
A101(LOW)
0.1[Hz]
1283h A102(HIGH)
1284h
A102(LOW)
1285h
A103
1 [%]
1286h
A104
26
20~100
00: Disabled
01: Enabled
02: Enabled (Operates only at set
frequency)
0~6000
0~50
0~100 (70)
0~600
00: Edge operation
01: Level operation
0
1st Frequency Lower Limit to 1st
Maximum Frequency
0
2nd Frequency Lower Limit to 2nd
Maximum Frequency
0
Starting Frequency to 1st Maximum
Frequency
0
Starting Frequency to 2nd Frequency
Upper Limit
0~40000 (In the high-frequency
mode︓~58000)
0~1000 (In the high-frequency
mode︓~10000)
00: Disabled
01: Enabled
02: Enabled (Reverse output
enabled)
0~2500
0~36000
0~10000
1~9999
00: Current (FI)
01: Voltage (FV)
02: Modbus communication
03: Pulse train frequency
10: Operation function output
00: Disabled (Deviation = Target
value − Feedback value)
01: Enabled (Deviation = Feedback
value Target value)
0~1000
00: Always ON
01: Always OFF
02: OFF during deceleration
200-V class:
00 (200)/ 01 (215)/ 02 (220)/ 03
(230)/ 04 (240)
400-V class:
05 (380)/ 06 (400)/ 07 (415)/ 08
(440)/ 09 (460)/ 10 (480)
00: Normal operation
01: Energy-saving operation
0~1000
0~360000
00: Switch via 2CH terminal ( multi-
function input: 09)
01: Switch by setting( A095/ A295/
A096/ A296)
0~40000 (In the high-frequency
mode︓~58000)
00: Line
01: S-shape curve
02: U-shape curve
03: Inverted U-shape curve
04: EL-S-shape curve
0~40000 (In the high-frequency
mode︓~58000)
0~100
1[%]
-
0.01[Hz]
0.1[s]
1[%]
0.1[s]
-
0.01[Hz]
0.01[Hz]
0.01[Hz]
0.01
0.1[s]
0.01[s]
0.01
0.1[%]
-
-
-
0.1[%]
0.01[s]
-
0.01[Hz]
-
0.01[Hz]
1[%]