Clean Up

Clean Up
1.
Perform Pressure Relief Procedure,
page 15.
2.
Remove Guard and SwitchTip.
3.
Remove displacement pump from paint
and place in flushing fluid. Use water for
water-based paint and mineral spirits for
oil based paint.
26
ti8687a
ti9692a
4.
Turn motor switch ON or turn engine ON
and start engine. Turn hydraulic pump
valve ON. Turn prime valve forward to
SPRAY position.
5.
Hold gun against pail. Disengage trigger
lock. Turn pressure control up until motor
begins to drive pump. Trigger gun until
flushing fluid appears.
I
O
ti25161a
ti5271b
PAINT
ti5272a
334606B