Startup (Gas Models) - Graco Standard Series Operation, Parts

Hydraulic sprayers
Hide thumbs Also See for Standard Series:
Table of Contents

Advertisement

Startup (Gas Models)

1.
Place displacement pump in grounded
metal pail partially filled with flushing
fluid. Attach ground wire to pail and to
earth ground.
2.
Turn prime valve down to DRAIN
position. Turn pressure control
counterclockwise to lowest pressure.
3.
Set hydraulic pump valve OFF.
334606B
ti9692a
ti9686a
Startup (Gas Models)
4.
Start engine.
a.
Move fuel valve to open.
ti5248a
b.
Move choke to closed.
ti5249a
c.
Set throttle to fast.
ti5250a
d.
Set engine switch to ON.
ti5262a
19