Dutymax Eh230Di Procontractor Series - Graco Standard Series Operation, Parts

Hydraulic sprayers
Hide thumbs Also See for Standard Series:
Table of Contents

Advertisement

Technical Data

DutyMax EH230DI ProContractor Series

Maximum fluid working pressure. . . . . . . . .
Hydraulic reservoir capacity . . . . . . . . . . . .
Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage, Amperage Frequency Phase
Maximum tip size. . . . . . . . . . . . . . . . . . . . .
Maximum free-flow delivery. . . . . . . . . . . . .
Hose connection . . . . . . . . . . . . . . . . . . . . .
Cycles per gallon
Sound Levels
(Measured at maximum normal load conditions)
Engine HP . . . . . . . . . . . . . . . . . . . . . . . . . .
Sound pressure
Sound power
Inlet/Outlet Sizes
Fluid inlet size in.. . . . . . . . . . . . . . . . . . . . .
Fluid outlet size in.. . . . . . . . . . . . . . . . . . . .
Weight
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Width
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Length
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Height
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
64
US
3300 psi
1.25 gallons
3.0 HP
220 VAC, 15.0 A,
50 Hz, 1 phase
1.56 gpm
3/8 npsm (f)
80
1 npt (m)
3/8 npt (m)
227 lbs.
26.5 in.
52 in.
39 in.
Metric
22.8 MPa, 228 bar
4.75 liters
2.2 kW
220 VAC, 15.0 A
50 Hz, 1 phase
0.039
5.9 l/min
21.1
3.0
80 dBa
95
103 kg
67 cm
132 cm
99 cm
334606B

Advertisement

Table of Contents
loading

This manual is also suitable for:

Procontractor seriesDutymax eh/gh 230Dutymax eh/gh 300

Table of Contents