Startup (Electric Models)

Startup (Electric Models)
1.
Place displacement pump in grounded
metal pail partially filled with flushing
fluid. Attach ground wire to pail and to
earth ground.
2.
Turn prime valve down. Turn pressure
control counterclockwise to lowest
pressure.
3.
Set hydraulic pump valve OFF.
22
ti9692a
ti9686a
4.
Plug cord into outlet.
For three phase electric motors: If red
phase sequence light is on, remove plug
from outlet and turn phase sequence
screw 180°.
ti18704a
5.
Turn motor ON.
ti18419a
6.
Set hydraulic pump valve ON (hydraulic
motor is now active).
ti18691a
ti18690a
I
O
ti9687a