Omron NX Series User Manual page 289

Io-link system
Hide thumbs Also See for NX Series:
Table of Contents

Advertisement

Step
7
Downloading EtherCAT
Slave Terminal Settings
8
Going Offline from Sys-
mac Studio and Turning
ON the Power of the Mas-
ter from the Other Compa-
ny
9
Reading the I/O Allocation
Settings (PDO Map Set-
tings) of the EtherCAT
Slave Terminal
10
Downloading the Network
Configuration Information
and Program to the Master
from the Other Company
11
Parameter Settings for IO-
Link Devices (as Required)
12
Downloading Parameter
Settings to IO-Link Devi-
ces (as Required)
13
Checking the Indicators on
the IO-Link Master Unit
and the IO-Link Devices
14
Checking the Error Status
of the IO-Link Master Unit
and the IO-Link Devices
*1.
If operation with Support Software other than Sysmac Studio is required, that Support Software is mentioned.
*2.
With Sysmac Studio version 1.29 or higher, you can use the IO-Link Master Simple Settings function for setting param-
eters and editing I/O allocation settings in one screen.
Refer to 8-2-4 IO-Link Master Simple Settings on page 8-15 for details on the IO-Link Master Simple Settings.
*3.
The default data size for each IO-Link device is 2 input bytes or 2 output bytes. The maximum data size for each de-
vice is 32 bytes.
For example, for OMRON IO-Link devices such as the E2E and E3Z, the default values can be used, and no additional
I/O entries are necessary.
For other I/O devices, such as those from other companies, additional I/O entries for the I/O data sizes of those devi-
ces are required.
NX/GX-series IO-Link System User's Manual (W570)
Contents
---
---
---
Create the network con-
figuration information
(ENI) based on the read
EtherCAT Slave Terminal
information and down-
load the information to
the master from the oth-
er company.
Download the program
to the master from the
other company.
If the default values are ac-
ceptable or if you set the
parameters with the actual
devices, you do not need to
change any settings.
Same as above.
---
---
Sysmac Studio opera-
*1
tion
Coupler Connection USB
- Transfer to Coupler
Coupler Connection USB
- Offline
Use the software applica-
tion from the other compa-
ny.
Use the software applica-
tion from the other compa-
ny.
---
---
---
---
Appendices
CX-ConfiguratorFDT op-
eration
---
---
---
---
Place the device DTMs of
the IO-Link devices under
NX Coupler USB - NX-
ILM400.
Set the IO-Link device pa-
rameters.
Connect CX-Configura-
torFDT to the EtherCAT
Coupler Unit, and down-
load the parameters from
the IO-Link devices.
---
---
A-7
A