Technical specifications - CloudConnect 716
Relative humidity
Permitted contaminant concentration
Design, dimensions and weight
Module format
Degree of protection
Weight
Dimensions (W x H x D)
Mounting type
* The current load due to an external consumer connected between VP (pin 6) and DGND (pin 5) must not exceed a maxi-
mum of 15 mA (short-circuit proof) for bus termination.
For further data, refer to section Application and functions (Page 11).
6.3
Pinout of the Ethernet interfaces
Pinout of the gigabit Ethernet interfaces
The table below shows the pin assignment of the two interfaces P1 and P2.
View of the RJ-45 jack
128
During transportation
During operation
Corrosive gas test according to ISA-S71.04 severity level G1, G2, G3
SO
2
H
S
2
Compact module S7-1500
IP20
400 g
35 x 147 x 127 mm
35 mm DIN rail mounting
S7-300 standard rail mounting
S7-1500 standard rail mounting
Wall mounting
Pin
1
2
3
4
5
6
7
8
-40 °C ... +70 °C
≤ 60 % at 25 °C, no condensation
< 0.5 ppm
< 0.1 ppm
Signal name
Assignment
D1+
D1+ bidirectional
D1-
D1- bidirectional
D2+
D2+ bidirectional
D3+
D3+ bidirectional
D3-
D3- bidirectional
D2-
D2- bidirectional
D4+
D4+ bidirectional
D4-
D4- bidirectional
Operating Instructions, 10/2019, C79000-G8976-C503-02