Configuration
4.11 Maintenance
● Security messages
You can save the security events here. Possible file formats: *.log, *.csv
● Diagnostic messages
Here you can save the diagnostic messages of the device in a compressed archive
"diagnostic.tqz".
Unzip the *.tqz archive and the following extracted *.tar archive. You can find the
diagnostic messages in a *.log file.
Security events
The gateway outputs Syslog messages according to RFC 5424 / RFC 5426. The messages
are based on IEC 62443-3-3.
When the address data of a Syslog server is input, the gateway sends the messages to the
server.
If you do not have a Syslog server, leave the server address free.
● Server address
Enter the IP address of the Syslog servers.
● Server port
You can change the default server port 514 (UDP).
You will find a description of the Syslog messages in the appendix Syslog messages
(Page 141).