Appendix E - System Events

Event Code and
String
Triggers
ECC1-R: Cavitation
The cavitation error generation logic is
Errors On
turned ON (default and recommended
state for production use).
ECC0-R: Cavitation
The user has turned OFF the
Errors Off
Cavitation Error Generation logic (not
recommended for production use).
This event also generates if cavitation
errors are off when the product
powers up. An error will not generate if
an HFR pump does not completely fill,
and the material ratio may be
incorrect.
ECD0-R: Mixer Motor
User has activated function (Pressed
Disabled for Dispense
"
effects on future dispenses.
ECD1-R: Mixer Motor
User has re-enabled the mixer motor
Enabled for Dispense
for dispensing.
ECF0-R: Mixer Air
User has activated function (Pressed
OFF for Dispense
"
effects on future dispenses.
ECF1-R: Mixer Air
User has re-enabled Air Nucleation for
Enabled for Dispense
dispensing.
ECGX: Dispense
The rate (flow or pressure) or amount
Recipe Altered by
has been altered by the controlling
PLC
CGM/PLC interface when the system
was in shot mode.
REL00: System Pow-
The System was powered on.
ered On
REM00: System
The System was powered off.
Powered Off
REB00: Stop Button
The Red stop button was pressed on
Pressed
the Advanced Display Module.
RECH0: Learn Mode
A learn mode calibration was success-
Executed
fully completed.
RENN0: Automatic
The system was successfully charac-
Cal. Performed
terized with the Automatic calibration.
RECA1: Red Material
The Red materials specific gravity was
SG Modified
modified.
RECB2: Blue Mate-
The Blue materials specific gravity
rial SG Modified
was modified.
RENC1: Cal. Point 1
A value for the first point in the three
Weight Entered
point calibration was entered.
RENC2: Cal. Point 2
A value for the second point in the
Weight Entered
three point calibration was entered.
RENC4: Cal. Point 1
The running average for point one of
Weight Erased
the three point calibration was erased.
RENC5: Cal. Point 2
The running average for point two of
Weight Erased
the three point calibration was erased.
3A2175Z
" key) which may have negative
" key) which may have negative
Event Code and
String
Triggers
REND0: Ratio Check
A ratio check shot was dispensed
Dispense
from the ratio check calibration
screen.
REA00: Disp.
A dispense has occurred of the given
Occurred (Shot #)
shot number.
REH00: Gel Timer
The gel timer expired and the system
Dispense
automatically took the gel shot.
RER01: Shot Count
A counter from the shot counters
Reset
maintenance page was erased
RER02: Seq. Posi-
A counter from the sequence counters
tion Count Reset
maintenance page was erased
RERA1: Red Material
The resettable totalizer for the Red
Volume Reset
material volume was reset to zero.
RERB1: Blue Mate-
The resettable totalizer for the Blue
rial Volume Reset
material volume was reset to zero.
RERA2: Red Material
The resettable totalizer for the Red
Weight Reset
material weight was reset to zero.
RERB2: Blue Mate-
The resettable totalizer for the Blue
rial Weight Reset
material weight was reset to zero.
RERA3: Red Cycle
The resettable cycle counter for the
Count Reset
Red pump was reset to zero.
RERB3: Blue Cycle
The resettable cycle counter for the
Count Reset
Blue pump was reset to zero.
REQU1: Settings
The system settings were successfully
Downloaded
transferred from the ADM to a USB
drive.
REQU2: Settings
The system settings file was success-
Uploaded
fully transferred from the USB drive to
the ADM.
REQU3: Language
The custom language file was suc-
Downloaded
cessfully transferred from the ADM to
a USB drive.
REQU4: Language
The custom language file was suc-
Uploaded
cessfully transferred from the USB
drive to the ADM.
REQU5: Logs Down-
The Error/Event and Shot data logs
loaded
were successfully transferred from the
ADM to a USB drive.
REAR0: Night Mode
While in night mode the system has
Recirc On
automatically entered a low recircula-
tion mode and attempted to turn on all
enabled conditioning zones.
REBR0: Night Mode
While in night mode the system has
Recirc Off
automatically stopped the low recircu-
lation mode and turned off all condi-
tioning zones.
Appendix E - System Events
97