Technical Data

Technical Data
Maximum Fluid Working Pressure:
HFRL Models . . . . . . . . . . . . . . . . 2000 psi (14 MPa, 138 bar) ‡
HFRS Models . . . . . . . . . . . . . . . . 3000 psi (21MPa, 207 bar) ‡
Maximum Fluid Temperature . . . . . . . 120°F (50°C)
Fluid Inlet Pressure at Inlet Fitting:
HFRL Models . . . . . . . . . . . . . . . . 50 psi (345 kPa, 3.4 bar) to 250 psi (1.8 MPa, 18 bar)
HFRS Models:
Regulator Inlet . . . . . . . . . . . . . 250 psi (1.8 MPa, 18 bar) to 3000 psi (21 MPa, 207 bar)
Pump Inlet (Regulator Outlet) . 250 psi (1.8 MPa, 18 bar) to 1500 psi (10 MPa, 103 bar)
Fluid Inlets . . . . . . . . . . . . . . . . . . . . . Component A (Red): 3/4 npt(f)
Fluid Outlets on Manifold. . . . . . . . . . Component A (Red): 1/2 in. npt(f)
Air Inlet. . . . . . . . . . . . . . . . . . . . . . . . 1/4 NPS
Air Inlet Pressure . . . . . . . . . . . . . . . . 40 psi (280 kPa, 2.8 bar) to 100 psi (0.7 MPa, 7 bar)
Fluid Circulation Ports . . . . . . . . . . . . 1/4 npsm(m), with plastic tubing, 250 psi (1.8 MPa, 18 bar) maximum
Line Voltage Requirement . . . . . . . . . 230V / 1 phase: 195-264V, 50/60 Hz
Peak Amperage Requirement . . . . . . 55A per phase @ full load *
System Watts. . . . . . . . . . . . . . . . . . . 12,650
Sound Power . . . . . . . . . . . . . . . . . . . 93 dB
Hydraulic reservoir capacity . . . . . . . 8 gal. (30 liters)
Recommended hydraulic fluid. . . . . . Citgo A/W Hydraulic Oil, ISO Grade 46
Weight . . . . . . . . . . . . . . . . . . . . . . . . 634 lb (288 kg) (Not including supply pumps)
Wetted Parts . . . . . . . . . . . . . . . . . . . Aluminum, stainless steel, zinc-plated carbon steel, brass, carbide, chrome,
All other brand names or marks are used for identification purposes and are trademarks of their respective owners.
*
Full load amps with all devices operating at maximum capabilities. Fuse requirements at various flow rates and
mix chamber sizes may be less.
approved.
‡ The maximum fluid working pressure for the base machine without hoses is 3000 psi (20.7 MPa, 207 bar). If
hoses rated at less than 3000 psi are installed, the system maximum fluid working pressure becomes the rating of
the hoses. If 2000 psi hoses were purchased and installed by Graco, the working pressure for the machine is
already setup for the lower 2000 psi (13.8 MPa, 138 bar) working pressure by Graco. If the machine was pur-
chased without hoses and aftermarket hoses rated at or above 3000 psi are to be installed, see instruction man-
ual 3A1276 for the procedure to setup the machine for higher rated hoses. The change in working pressure is
made by changing a rotary switch setting in the Motor Control Module. The minimum pressure rating for hoses is
2000 psi. Do not install hoses with a pressure rating lower than 2000 psi.
138
See Models starting on page 4 for specific flow rate and pressure information
Component B (Blue): 3/4 npt(f)
Component B (Blue): 1/2 in. npt(f)
400V / 3 phase: 360-440V, 50/60 Hz; see 400 V Power Requirements, page
5 and page 7; ★
fluoroelastomer, PTFE, ultra-high molecular weight polyethylene, chemically
resistant o-rings