Hfr-Silicone (Hfrs) - Graco HFRL Setup And Operation Manual

Table of Contents

Advertisement

Models

HFR-Silicone (HFRS)

HFRS models are designed for use with high viscosity, unheated silicone adhesives at flow rates of up to
20 cc/sec (3 lb/min) @ 2500 psi (17 MPa, 172 bar). The equipment can be run at up to 20 cycles per minute
continuous duty.
A Pump
B Pump
Size
Size
10
100
15
80
40
40
10
60
20
40
10
40
10
10
** Cycle rate should be between 3 and 20 cycles per minute. Max flow rate is determined for continuous service at
120°F (39°C) at stated cpm and pressure. Higher cycle rates are possible at lower temperatures/pressures and
intermittent use. Lower cycle rates may be possible, but should be tested under application conditions.
Flow rates are established @ 2500 psi (17 MPa, 172 bar). Dispense rate in excess of max flow and pressure may
result in an elevated temperature of the hydraulic system, resulting in a thermal shutdown (T4H1). Other system
models are available for sustained flow rates and pressures in excess of above.
6
Required cpm@
cc/cycle
Maximum Flow**
110
11
95
12.5
80
15
70
17
60
20
50
20
20
12
Minimum Flow †
Maximum Flow †
cc/sec
5.6
4.8
4
3.6
3
2.5
1
cc/sec
Ratio
20
10.00
20
5.33
20
1.00
20
6.00
20
2.00
16.7
4.00
4
1.00
3A2175Z

Advertisement

Table of Contents
loading

Table of Contents