9. Turn in the stopper max flow to get swivel angle zero.
10. Disassemble the rotary group in horizontal position.
11. Disassemble the stopper - max. flow.
12. Remove the threaded pin (stopper - max.flow).
3121201
SECTION 3 - CHASSIS & TURNTABLE
13. Disassemble the plug.
14. Disassemble the control piston while moving the swash
plate.
15. The swash plate must be lifted a little bit to disassemble
the piston rod.
16. Disassembly of the swash plate.
3-33