Canon imageCLASS D600s Service Manual page 79

Hide thumbs Also See for imageCLASS D600s:
Table of Contents

Advertisement

CHAPTER 2 USING THE MACHINE
#1 SSSW-SW12: page timer setting
Bit
Function
0
1-page time-out length for trans-
mission
1
2
1-page time-out length for trans-
mission (HT transmission)
3
4
1-page time-out length for re-
ception
5
6
not used
7
page timer setting by transmis-
sion/reception
The machine is designed to stop communication when transmission/reception of a single
page takes 32 min or more. To set a time-out length, refer to the next page.
If '1' is selected for bit 7, the 1-page time-out length will be as set by bit 0 and bit 1.
2-36
COPYRIGHT © 2001 CANON INC.
Chapter2.p65
1
1
1
1
1
1
1
set
CANON imageCLASS D600s/PC1060s/PC1200s/iR1200s REV. 0 SEPT. 2001
36
0
Factory setting
0
1
0
1
0
0
0
0
0
0
0
0
0
do not set
0
8/26/01, 3:42 PM